The space can provide forward or parallel access to the bathroom equipment and part of the area can underneath the equipment as long as there is enough clearance for the knees and toes of the person in the wheelchair.
Minimum ada toilet stall size.
The required minimum floor space for a handicapped accessible bathroom is 30 inches by 48 inches.
Figure 30 a standard stall.
2010 standards minimum with out swinging door.
Distances should allow for common usage by people with a limited range of motion.
This plan shows a typical example of a single user toilet room that meets the minimum requirements of the 2010.
Where toilet rooms are provided in multi story facilities that are exempt from the requirement for vertical access between stories 206 2 3 ex.
Multiple toilet stall layouts.
An example of a single ada bathroom layout.
Accessible toilet stalls or compartments must have a minimum width of 60 inches and sufficient space to accommodate a wheelchair to the sides of the toilet or in front of it.
Figure 30 a standard stall.
The minimum width of the stall is 60 inches 1525 mm.
If toilet stall approach is from the latch side of the stall door clearance between the door side of the stall and any obstruction may be reduced to a minimum of 42 in 1065 mm.
The standards specify the location of toilet rooms in two instances.
1 or 2 a toilet room must be provided on a story that is connected to an accessible entrance by an accessible route 213 1.
However stall depth can be anywhere between 48 inches to 78 inches as needed.
Generally stall doors open inward but for ada accessible stalls the doors should open outward to make it easier for those with accessibility.
The size of this room requires that the entry door swing out.
Dimension guidelines when dispensers protrude from the wall in toilet rooms and toilet compartments.
For commercial bathrooms with multiple toilet stalls and handicap the rules change a little.
The location of the door is in front of the clear space and diagonal to the water closet with a maximum stile width of 4 inches 100 mm.
Horizontal grab bars must be installed behind the toilet and on the nearest wall or partition whichever is closer.
7 0 x 5 0 35 00 square feet.
The minimum width of the stall is 60 inches 1525 mm.
The centerline of the water closet is 18 inches 455 mm from the side wall.
In a corner handicap stalls require a minimum of 60 x 60 compartment and is required with a minimum door size of 32 and the maximum size and more common is the 36 door.
There are many dimensions to consider when designing an accessible bathroom stall.